Product Description
Specifications 1)
Soundproof Generator 2)low fuel consumption
3)durable performance
4)global warranty
5)CE,ISO,SGS,SONCAP,OEM
18kw-800kw super
Silent Diesel Generator The specification of silent
diesel generator :
Genset model | SC |
Type | open/sound proof/weather proof |
Genset output power range | 18kw-800kw |
Rated voltage | 220/380V,230/400V,240/415V,120/240V |
Frequency | 50/60HZ |
Power factor | 0.8 |
Rated speed | 1500/1800rpm |
output type | AC three phase/single phase |
Motor | brushless |
Frequency | <3% |
Frequency at stable state: | <0.5% |
Frequency deviation at instantaneous state | ≤+10% |
Frequency return time | ≤3s |
Voltage deviation at stable state | ≤±1% |
Voltage deviation at instantaneous state | ≤+20% |
Voltage return time | ≤4s |
Voltage modulation | ≤0.3% |
The specification of engine of silent
Diesel Generator:
Model | 4B3.9-G,4BT3.9-G,4BTA3.9-G,6BT5.9-G,6BTA5.9-G,6BTAA5.9-G,6CTAA8.3-G,6LTAA8.9-G, NTA855-G, KTA19-G, KTAA19-G, KT38-G, KTA38-G, KTA50-G |
Cooling Method | water cooled |
Rotating speed | 1500/1800rpm |
Governor system | electrical or mechanical governor |
Aspiration mode | natural aspirated or turbocharged |
Starting method | 12/24V DC electric starting |
Stroke | 4 stroke |
The specification of alternator of silent diesel generator:
Brand | Stamford, Leroy semor, Maraton etc. |
Regulator | AVR automatic voltage regulating |
Excite type | pret or shunt |
Connecting type | 3PH star, 3PH-DELTA |
Steady frequency change | 0-5% |
No load voltage | ≥95%-105 |
Steady voltage | ≤±1 |
Insulation degree | H degree |
Exclosure degree | IP23 |
silent generator use of safety norms
1.Operators sould be familiar with the operation of generating units, operating methods, and all control bodies, manual valves, stopping body position.
2.In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1)Uints exist electric shocks danger;
(2)Uints exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4.Engine room or other nearest shouldmaintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers).
5.Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6.Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7.Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dcpower supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be nitified stop all of this unit operation.
9.To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10.Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.
Contact us if you need more details on Soundproof Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Soundproof Generator、Soundproof Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Silent/Soundproof Generator