Product Description
Factory direct sale! 500kva
diesel generator with auto start 500kva generator feature, specification, photos and prices 500kva generator feature 1. Global warranty 1 year. 2. We are the OEM of Cummins engine. 3. we supply spare parts during the whole service life. 4. 500kva Cummins generator with alternator can be world famous Stamford, Leroy Somer, Marathon, Siemens,etc. 5. Key start / auto start
6. Sound-proof / weather-proof canopy is optional
7. 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output
8. Frequency: <3%
9. Frequency at stable state: <0.5%
10. Frequency deviation at instantaneous state: ≤+10%
11. Frequency return time: ≤3s
12. Voltage deviation at stable state: ≤±1%
13. Voltage deviation at instantaneous state: ≤+20%
14. Voltage return time: ≤4s
15. Voltage modulation: ≤0.3% 1. 500kva generator specification
500kva Diesel Generator |
Genset Model | open type | SC400GF |
Prime Power(kva) | 500 |
Standby Power(kva) | 550 |
Rated Current(A) | 720 |
Overall Size(mm) | Length(mm) | 3500 |
Width(mm) | 1375 |
Height(mm) | 1980 |
Gross Weight(kg) | 3950 |
|
diesel engine | Model | KTA19-G4 |
Type | water-cooled,4-stroke,direct injection,wet cylinder liner |
Rated Power(kva) | 570 |
Intake Type | Turbocharged |
No.of Cylinder | 6.L |
Bore x Stroke(mm) | 159*159 |
Compression ratio | 14.5:1 |
Lub oil Capacity(L) | 50 |
Rated Fuel Consumption(L/h) | 90 |
Displacement(L) | 18.9 |
Starting method | DC 24V Electric starter |
Governing Type | Electric governor |
Alternator | Model | HCI544D |
Rated Power(kva) | 500 |
Power Efficiency | 93.30% |
Frequency(Hz) | 50 |
Excitation Type | Brushless |
Insulation Class | H |
2. 500kva cummins generator Control panel and ATS 1) Control system: a) Automatic alarm system: the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current b) Operation display: i) Unit voltage, tri-phase load current and frequency display ii) Water temperature, oil pressure display iii) Fuel level, fuel temperature display iv) Audible and visual alarm lamps and buzzers
2) Starting system: starter is used to start engine 3) Short circuit protection: MCCB air switch 4) Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C 5) Filter system: oil, fuel and air filter 6) Accessories: exhaust elbow, bellow, muffler 3. Supply standard collocation a)
Diesel Engine with all accessories, 3 filter, electric systems b) Alternator c) Steel structure d) Fan and water tank cooling system e) Flange connector f) 12 / 24V starting motor and charge engine g) Air cleaner, fuel cleaner, oil cleaner h) On-board control panel i) MCCB air conservation switch j) 12 / 24V starting accumulator and battery line k) Set shock absorber l) High-efficient silencer 8) Automatic Transfer Switch
5. Factory
Use of safety norms
1.Operators sould be familiar with the operation of generating units, operating methods, and all control bodies, manual valves, stopping body position.
2.In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1)Uints exist electric shocks danger;
(2)Uints exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4.Engine room or other nearest shouldmaintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers).
5.Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6.Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7.Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dcpower supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be nitified stop all of this unit operation.
9.To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10.Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation. Contact directly
Contact us if you need more details on 500kva Diesel Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Generator Qsk23-g3、6cta8.3g2 Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.